Difference between revisions of "Template:Fish guidance structures with narrow and wide bar spacing"

From FIThydrowiki
Jump to navigation Jump to search
(Making templates for classification tables)
(Updating classification tables: Adding FIThydro colors)
 
(7 intermediate revisions by the same user not shown)
Line 1: Line 1:
Fish guidance structures with narrow and wide bar spacing
 
 
{| class="wikitable"
 
{| class="wikitable"
 +
! colspan="2" style="text-align: center; background-color:#2cb4da; color:#ffffff;" |Fish guidance structures with narrow and wide bar spacing
 +
|-
 
! Classification !! Selection
 
! Classification !! Selection
 
|-
 
|-
Line 13: Line 14:
 
||Recurrence of maintenance||[[Recurrence of maintenance::Weekly]]
 
||Recurrence of maintenance||[[Recurrence of maintenance::Weekly]]
 
|-
 
|-
|rowspan = "6"|Which life-stage of fish is measure aimed at||-
+
|rowspan = "4"|Which life-stage of fish is measure aimed at||-
|-
 
||-
 
|-
 
||-
 
 
|-
 
|-
 
||-
 
||-
Line 23: Line 20:
 
||-
 
||-
 
|-
 
|-
||[[Which life-stage of fish is measure aimed at::Movements of migration of fish]]
+
||[[Which life-stage of fish is measure aimed at::Movements and migration of fish]]
 
|-
 
|-
|rowspan = "8"|Which physical parameter is mitigated||[[Which physical parameter is mitigated::N/A]]
+
|rowspan = "8"|Which physical parameter is addressed||[[Which physical parameter is addressed::Barriers]]
 
|-
 
|-
 
||-
 
||-
Line 43: Line 40:
 
|rowspan = "2"|Hydropower type the measure is suitable for||[[Hydropower type the measure is suitable for::Plant in dam]]
 
|rowspan = "2"|Hydropower type the measure is suitable for||[[Hydropower type the measure is suitable for::Plant in dam]]
 
|-
 
|-
||-
+
||[[Hydropower type the measure is suitable for::Plant with bypass section]]
 
|-
 
|-
 
||Dam height (m) the measure is suitable for||[[Dam height (m) the measure is suitable for::All]]
 
||Dam height (m) the measure is suitable for||[[Dam height (m) the measure is suitable for::All]]
Line 55: Line 52:
 
||-
 
||-
 
|-
 
|-
|rowspan = "3"|River type implemented||-
+
|rowspan = "3"|River type implemented||[[River type implemented::Steep gradient (up to 0.4 %)]]
 
|-
 
|-
 
||[[River type implemented::Fairly steep with rocks, boulders (from 0.4 to 0.05 %)]]
 
||[[River type implemented::Fairly steep with rocks, boulders (from 0.4 to 0.05 %)]]
Line 61: Line 58:
 
||[[River type implemented::Slow flowing, lowland, sandy (less than 0.05 %)]]
 
||[[River type implemented::Slow flowing, lowland, sandy (less than 0.05 %)]]
 
|-
 
|-
||Level of certainty in effect||[[Level of certainty in effect::Moderately certain]]
+
||Level of certainty in effect||[[Level of certainty in effect::Very certain]]
 
|-
 
|-
 
||Technology readiness level||[[Technology readiness level::TRL 9: actual system proven in operational environment]]
 
||Technology readiness level||[[Technology readiness level::TRL 9: actual system proven in operational environment]]
 
|}
 
|}

Latest revision as of 14:35, 16 January 2020

Fish guidance structures with narrow and wide bar spacing
Classification Selection
Fish species for the measure All
Does the measure require loss of power production Operational (requires flow release outside turbine)
-
-
Recurrence of maintenance Weekly
Which life-stage of fish is measure aimed at -
-
-
Movements and migration of fish
Which physical parameter is addressed Barriers
-
-
-
-
-
-
-
Hydropower type the measure is suitable for Plant in dam
Plant with bypass section
Dam height (m) the measure is suitable for All
Section in the regulated system measure is designed for In dam/power plant
-
-
-
River type implemented Steep gradient (up to 0.4 %)
Fairly steep with rocks, boulders (from 0.4 to 0.05 %)
Slow flowing, lowland, sandy (less than 0.05 %)
Level of certainty in effect Very certain
Technology readiness level TRL 9: actual system proven in operational environment